Model FE
Through Wall,
Extreme Environment
Reference Electrode
by Electrochemical Devices, Inc.

The Model FE is designed to
operate in extreme environments with high temperatures, high pressures and / or
contaminated electrolytes where ordinary reference electrodes cannot survive. A permanent
bridge is installed at each location where potential readings are desired. The reference
element is contained in a separate housing which isolates it from the aggressive
environment; this substantially increases its service life. When continuous readings are
required, the reference is threaded into the bridge. For intermittent readings, the
reference is simply pressed into the bridge. This allows a single reference to be used
with several bridges. Further details are shown on the following pages.
Typical Applications
- Oil separators, heater treaters, bleach tanks, industrial
boilers and process vessels.
Features
- Two-piece design which isolates the reference element from
the environment.
- Permanently installed bridge fabricated from G-10 (a glass
reinforced epoxy) should not need replacing.
- Removable CPVC housing which contains the reference element.
Bridge Specifications
- 1" NPT x 3" SS nipple
- 3/4" dia G-10 extension, length to suit
- 3/8" NPT-F junction well
- Pressure rated to 50 psi
- Max. process side temp. +200oF
Body Specifications
- 1" dia x 5 " CPVC body with smooth or threaded
junction
- Smooth - Slip-fit junction
- Threaded - 3/8" NPT-M junction
- 1/4-20 x ½" threaded stud termination
Element Types
- AGG - Saturated gelled Ag / AgCl
- CUG - Saturated gelled Cu / CuSO4
Operating Instructions
The Model FE reference electrode consists of two pieces:
- The bridge which is permanently installed in the vessel, and
- The reference which can be either permanently installed or
temporarily inserted when measurements are required.
All bridges are factory tested to 150 psi. The bridge is
designed to leak slightly in service to ensure good conductivity; the quantity of liquid
emitted will be proportional to the pressure differential across the bridge.
|

Temporary Electrode Installation
In a temporary installation, the reference electrode is
inserted into the bridge whenever a potential measurement is required. In between
readings, the 3/8" pipe plug must be installed in the bridge; at pressures over 50
psi, the 1" end cap must also be used. If the plug and cap are installed without any
joint compound or gaskets, the bridge will leak slightly to relieve the pressure buildup.
If a leak-free installation is required, use Teflon tape or a non-hardening Teflon pipe
dope on the threads.
Whenever the end cap or pipe plug is removed, it should be
assumed that the liquid behind it is under pressure. The cap should be slowly loosened to
bleed off the pressure; once the leakage has stopped, the cap can be removed. The same
procedure must be repeated when removing the plug.
|

Permanent Electrode Installation
For maximum electrode life, the electrode should be
installed into the bridge using no pipe thread sealants or gaskets. A small amount of
liquid will leak from the joint preventing a pressure buildup inside the bridge. Should a
leak-free joint be required, then the appropriate sealants and the supplied gasket can be
used. Note, however, that if the gasket is used, the bridge will be operating at the
vessel pressure which can force some of the vessel contents into the electrode and shorten
its life.
To replace a permanently installed electrode, it is not
necessary to drain the vessel since the bridge remains permanently installed. Loosen the
electrode just enough for the joint to start leaking which will relieve any pressure at
the end of the bridge. When the leaking stops, continue to slowly unscrew the electrode
until it is removed. A new electrode can then be installed.
Safety Precautions
Appropriate safety equipment as required by the vessel
contents and pressure must be used whenever the pipe plug, end cap or electrode is removed
from the bridge. At a minimum, suitable eye protection must be used even if the vessel
only contains water. It is always possible that a small amount of liquid will spray out
under pressure when the plug, cap or electrode is first loosened.
Dimensions
|

Model Designation, Bridge
- Specify as EDI Model FE-BDG-n.n, where n.n
= extension length in 0.5" increments (1" min., 6" max.).
Model Designation,
Body
- Specify as EDI Model FE-xxx-STy, where xxx
= element type and y = junction style (S for smooth, T for threaded).
|
|