Model IR
Regular Immersion
Reference Electrode
by Electrochemical Devices, Inc.
The Model IR
reference electrode is designed for long term installation in an aqueous
environment. It can be directly suspended by its lead wire or securely
attached to a steel structure with an optional magnetic mount. Antifreeze
protection is also available for situations where the electrode may be exposed to
temperatures down to -70oF.
Typical Applications
- Elevated water tanks, stand pipes, ground storage tanks,
clarifiers, traveling screens, trash racks, submerged pipelines, locks, dams, dock
structures.
Features
- Rugged 1 " Schedule 40 white PVC housing
- 15-year design life
- Optional magnetic mount for easy attachment to steel
structure
- Optional antifreeze protection to -70oF
Housing Specifications
- 1 5/8" dia. x 10 3/4" long PVC
- Heavy duty strain relief'
Element Specifications
- Design life: 15 years
- Shelf life: 1 year with end cap in place
- Maximum temperature: +140oF
- Minimum temperature: +10oF
Element types
- AGG: Saturated gelled Ag / AgCl
- CUG: Saturated gelled Cu / CuSO4
Terminations
- LWnnn: nnn ft. #12 AWG THHN
- CWnnn: nnn ft. of custom wire
Dimensions

Options
- IR: Regular (no options)
- IM: Magnetic mount
- IA: Antifreeze protection to -70oF
- IB: Magnetic mount & antifreeze
Model Designation
- Specify as EDI Model IZ-XXX-YY, where Z
= option code, XXX = element type, and YY = termination
type.
|
|