STELTH
7
IR Free, Stationary
Reference Electrode
by Borin

Features
- Minimum 20-year service life.
- 28 square inches of sensing surface area gives 9 to 35 times
more surface areas than other electrodes. This makes electrode positioning less critical
to achieve accurate readings.
- Will not dry out in desert dry soil, a condition that
renders other electrodes ineffective. Cyclical variations in soil conditions, ranging from
hydrated to dehydrated, have no adverse effect on the Stelth2 electrode.
- Will not be destroyed by absolute dry soil conditions. It
will only lie dormant until moisture returns. Electric Mud tm backfill will keep Stelth2
in a moisture environment which keeps it continuously active.
- Electrode may be taken out of service for extended periods
of time and reintroduced into the system without affecting electrode accuracy or ability
to reactivate. Electrode will fire up in under 5 minutes.
- Technologically advanced chloride ion trap prevents chloride
contamination of electrolyte.
- Available in three models: Cu-CuSO4, Ag-AgCl,
Zn-ZnSO4.
- Color coding matches industry standards. Electrode and wire
are both color coded for quick and easy remote identification of electrode chemistry.
- Fully compatible in a gelatin backfill environment such as
Electric Mud tm.
- Stability: 10 millivolts with 3 microamp load.
- Temperature Range: +32oF to +135oF (0oC
to 57.2oC)
- Complete installation instructions included.
|

 |
IR-Free
Potentials
An IR Free Potential is a potential
measured at the exact point where the surface of the structure meets the surrounding
environment. A potential measurement at this point is not distorted by the soil resistance
between reference electrode and the structure's surface.
IR-Free
Stationary Reference Probe
The "Stelth7" IR-Free reference probe
is designed to provide an IR Free Potential reading that is as close as theoretically
possible to that point where the structure and environment meet. This is achieved by
combining into a "PROBE" the proven Stelth technology and a precision mild steel
coupon which, when placed in the same soil conditions as the structure, will be exposed to
the identical forces acting upon this structure's flaws or holidays (exposed areas) such
as the cathodic protection system, stray currents and environmental conditions.
|
 |

How to set-up
and measure with the "Stelth 7" probe
The "Stelth7" probe is connected to your
structure through a test station. Two wires are connected to the structure and are brought
into the test station and connected to terminals four and five. Two wires connected to the
steel coupon in the probe are brought into the test station and connected to terminals one
and two. The third wire connected to the reference electrode in the probe is brought into
the test station and connected to terminal three. A shunt is placed across terminals one
and four Your potential reading is taken across terminals two and three.
|

How to Order
Model Numbers
- SRE-022-CIY: Cu-CuSO4
- SRE-023-SIB: Ag-AgCl
- SRE-024-ZIR: Zn-ZnSO4
|
|