Farwest Corrosion
Control Company
 

Home Products Services Contact Us Request Quote Order Online

 
 

 Navigation:  Home > Products > Instruments > Diagnostic Instruments > Current Interrupters

MicroMax® GPS200 Interrupter
by American Innovation


A proven, cost effective, portable GPS satellite synchronized interrupter
fully programmable in continuous, daily, dated and interference modes.

Features

  • Interference and Influence Mode
  • Relay independent
  • Interrupt multiple rectifiers with one GPS200
  • Store up to 9 interruption schedule
  • Auto-resume after power loss (no need to reset interrupter)

Description

American Innovations’ i-series MicroMax® GPS200 Interrupter is a proven, cost effective, portable GPS satellite synchronized interrupter that is fully programmable in continuous, daily, dated and interference modes. The GPS200 is compatible with all other brands of GPS synchronized interrupters or loggers. Users can define and store nine different programs for later recall. Cycle range is up to 999.9 seconds in 0.1 second increments. The unit automatically resumes its programmed cycle if a power disruption occurs. After hours, the unit can be set to automatically generate full CP polarization.

The GPS200 supplies 500 mA to drive an external relay or multiple relays. The external relay configuration and the user configurable nature of the relay controller output allows for use of the standard relay supplied with the interrupter or a custom relay. Standard relays are 30A Hg, 60A Hg, 100A Hg., 90A / 240 VAC solid state, and 100A / 100 VDC solid state. Interrupter output is user selectable and highly flexible. The output can be configured to 0V or 12V for ON or OFF. Synchronization can be set to be on the leading or falling edge of the interruption cycle. An on-board keypad and a display enable easy field programming.

The GPS200 comes in a weatherproof, extremely rugged, portable enclosure. It is powered from 100 to 280 Volts AC or 8 to 30 Volts DC. The MicroMax GPS200 is supplied complete with AC cable, DC cable, output cable and GPS antenna, all packaged in a canvas tool carry bag for easy handling.

Operation

Measures interference from multiple pipelines and multiple rectifiers, and/or measures influence from multiple rectifiers on one pipeline.

American Innovation's unique, patented Interference Mode interruption cycle enables interference testing with greatly increased productivity and ease of data interpretation. By operating in Interference Mode, it is possible to determine the influence from multiple rectifiers and capture the instant off pipe-to-soil potentials, all during a single visit to a test station!! In this mode, up to 99 GPS200 interrupters can be configured to switch multiple rectifiers so that IR-free pipe-to-soil potentials as well as the influence from each rectifier under investigation can be easily collected.

The same Interference Mode algorithm can be used on a single pipeline, using the methodology outlined above, to enable you to complete an “Influence Survey”. This methodology facilitates an accurate evaluation of each rectifier’s influence over the span of the pipeline.

Technical Specifications
    

Supply Voltage

AC: Between 80 VAC-240 VAC, DC: Min 10V, Max 14V. American Innovations does not recommend that an interrupter be powered from a rectifier DC output.

Output Voltage

On: 12.0V, Off: 0.0V

Physical Dimensions

9.12" x 7.56" x 4.37" (H x L x W)

Input Connections

2 inputs: one for DC Voltage (Min: 10V, Max: 14Vv), one for AC power (80-240 VAC)

Battery

Not included.

Operating Temperature

-40°C to +85°C

Enclosure Options

Weatherproof, extremely rugged, portable Pelican™ case enclosure

Included Equipment

Instrument, AC cable, DC cable, output cable, and GPS antenna with integral cable, all packaged in a canvas tool bag for easy handling.

Standard Relay Capacity

100A / 100V

Relay Control Current

500 mA (12V)

Relay Options

30 Amp Hg, 60 Amp Hg., 100 A Hg., 90 A/240 VAC solid state, 100 A/100 VDC solid state or custom

 

Instruments & Test Equipment

 Hand-held Multimeters
 Current Clamps & Meters
 Portable Multimeters
 Potential Meters
 Dataloggers & CP Survey
 Current Interrupters
 Power Supplies
 Soil Resistance Meters
 Pipe & Short Locators
 Insulation Testers
 Short - Holiday Detectors
 Coating Thickness Gauge
 Ultrasonic Thickness G.
 Test Reels & Wire

  

Cathodic Protection Products & Materials

  

Cathodic Protection Services

 Farwest Engineering
 Farwest Installation

  

Cathodic Protection of Offshore Structures

 Galvanic CP Systems
 Impressed CP Systems
 Attachment Systems
 Monitoring Equipment

  

Marine Products Division

 Marine ICCP Systems
 Galvanic CP Materials
 Marine Anti-Fouling
 Electrolytic De-Scaling
 Electro-Chlorination
 Marine CP Monitoring
 Galvanic Isolators

  

Pipeline Protection Products Division

 Epoxy Coatings
 Heat-Shrink Coatings
 Mastic Coatings
 Petrolatum Coatings
 Tape Coatings
 Surface Decontamination
 Moisture Seal Products
 Rockshields

 Insulated Fittings
 Insulators & Seals
 Pipeline Casing Fillers
 Flange Insulation
 Pipeline Cleaning Pigs
 Composite Systems
 Accessory Products
  

More Farwest
Website Resources

 Farwest News
 Search this Website
 Request Quote
 Order Products Online
  
 

Home

Products Services Search Request Quote Order Online

Farwest Corrosion Control Company
888-532-7937   (888-5FARWEST)
Complete Cathodic Protection™

Tel: 

 310-532-9524
Fax:  310-532-3934

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.farwestcorrosion.com

© 1996-2011 Farwest Corrosion Control Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956