Navigation:
Home >
Products >
Instruments >
Diagnostic
Instruments >
Data
Logger & CP Survey Equipment
Gx Data-Loggers
by MC Miller Co.

The MC Miller Gx Site Survey Data-logger and Gx
Pipeline Data-logger
come loaded with advanced features and applications software.

|
The following items are included with both
Gx Data-logger models.:
(more
info on Gx Data-logger parts) |
- Gx Data-logger
- Hard plastic
carrying case
- GPS thumb antenna
- AC charger/adapter
|
- Vehicle charger
- USB adapter cable (A
to mini-B)
- USB host cable (A to
mini-B)
- Serial cable
|

Two Gx Data-logger Models:
|
 |
 |
|
Gx Site Survey Data-logger |
Gx Pipeline Survey Data-logger |
Gx Site Survey Data-logger, Cat. # 11250
- Comes loaded with M.
C. Miller’s Test Site Survey software application.
- Integrates with
ProActive, M. C. Miller’s corrosion control data
management application.
- Data-types are
customizable for each of your test sites and each
test site can be GPS position stamped.
- High-resolution
date/time stamped photos can be taken at your test
sites during a route and recorded images are posted
directly to the ProActive database.
- User Manual
Gx Pipeline Survey Data-logger, Cat. # 11275
- Comes loaded with M.
C. Miller’s Pipeline Survey software application for
“Over-the-Pipe” Surveys:
- Close Interval Potential Surveys (CIPS or CIS)
- DCVG Surveys
- Combined (single-pass) DCVG/CIS Surveys
- Surface Potential Surveys
- Integrates with M.
C. Miller’s survey accessory equipment (see Package
Assembly Wizard).
- Integrates with
ProActive, for pipeline survey data management, or
can export data to Excel
High-resolution date/time stamped photos can be
integrated with your survey data.
- User Manual
|

|
Optional Software Applications for Gx Data-loggers:
The Gx Site Survey
Data-logger and the Gx Pipeline Survey Data-logger come
loaded with the appropriate software. In addition, these
data-loggers can be used to run other M. C. Miller
software applications that can be purchased separately:
- Gx Site Survey
Application (for the Gx Pipeline Survey
Data-logger), Cat. #SFT131
- Gx Pipeline Survey
Application (for the Gx Site Survey Data-logger),Cat.
#SFT132
- Gx Time Chart
Recorder Application, Cat. #SFT133
Software Support:
This is an optional item
that is highly recommended and includes access to the M.
C. Miller Help Desk as well as software updates and
enhancements as they are made available. This support is
included free-of-charge for the first year and can be
purchased before the end of the first year of ownership
of the data-logger and then annually thereafter.
- User Support for the
Gx Site Survey Application, Cat. #SFT131
- User Support for the
Gx Pipeline Survey Application. Cat. #SFT132
- User Support for the
Gx Time Chart Recorder Application, Cat #SFT133
|

General Specifications
- Integrated M. C.
Miller voltmeter.
- Integrated GPS
receiver (WAAS-enabled).
- Built-in 5MP digital
camera with auto-focus and illumination.
- Serial port
available for an external GPS receiver connection,
if required.
- 320x240 pixel (3.5
inch) color LCD touch-screen (indoor/outdoor
viewing).
- 55-key
alphabetic-order keypad.
- Windows CE 5.0
operating system.
- Xscale processor
(624 MHz).
- 256MB SDRAM.
- 2GB SD card
(non-volatile memory for survey data storage).
- Serial (RS232) & USB
outputs.
- Bluetooth-enabled.
- Two re-=chargeable
2500 mAh Li-Ion batteries (5000 mAh total capacity)
[40+ hours operation*]
- IP67 rated (1 meter
immersion).
- Satisfies
MIL-STD-810F (wind-blown rain).
- Operating temp
range: -4°F to 122 °F (-20°C to 50°C).
- Storage temp range
(no battery): -4°F to 140°F (-20°C to 60°C).
- Dimensions: 12.5” x
5.31” x 2.31”
- Weight: 2.64 lbs
|

|
Range |
Input
Impedance |
Response
Time |
Display
Resolution |
Accuracy
(% of reading) |
|
40 mVdc |
10 MΩ |
80 ms |
0.01mV |
±0.2% ±0.08 mV |
|
400 mVdc |
10 MΩ |
80 ms |
0.1mV |
±0.2% ±0.6 mV |
|
5.7 Vdc |
400 MΩ |
80 ms |
1 mV |
±0.2% ±0.004V |
|
40 Vdc |
75 MΩ |
80 ms |
10 mV |
±0.2% ±0.04V |
|
57 Vdc |
75 MΩ |
2 ms |
10 mV |
±0.2% ±0.04V |
|
57 Vdc |
75 MΩ |
50 ms |
10 mV |
±0.2% ±0.04V |
|
400 Vdc |
75 MΩ |
80 ms |
100 mV |
±0.2% ±0.4V |
|
570 Vdc |
75 MΩ |
2 ms |
100 mV |
±0.2% ±0.4V |
|
40 Vac |
75 MΩ |
1.35 s |
10 mV |
±0.2% ±0.06V |
|
400 Vac |
75 MΩ |
1.35 s |
100 mV |
±0.2% ±0.6V |
|
Key Voltmeter Characteristics
-
High Voltage
Isolation for Operator Safety: Tested to 1 kV
steady-state/15 kV transient voltage levels
(designed for higher voltage level isolation). Meets
the IEC Standard for Category IV environments.
-
Analog Pre-Processing
& Digital Signal Processing (DSP): Accurate
determination of On/Off pair values. Voltmeter does
not saturate even with superimposed AC signals (up
to 120V) and/or inductive spikes (up to 2 kV)
appearing at the input terminals.
- Fast Response
Channels (Ranges) Available: 80ms response time
in combination with high input impedance values (up
to 400 MΩ). Accurate On/Off pair readings during
fast cycle current interruption, even under high
source resistance conditions.
|

|