Specifications |
|
Maximum voltage |
| |
600V between any
terminal and earth ground |
|
|
Surge protection |
| |
6 kV peak per IEC
61010-1 600 VCAT III, Pollution Degree 2 |
|
|
Display |
|
Digital: |
6,000 counts,
updates 4 per second |
|
|
Bar graph |
| |
33 segments, updates
32 per second |
|
|
Operating Temperature |
|
|
Storage Temperature
|
|
|
Battery type |
| |
9V alkaline, NEDA
1604A/ IEC 6LR61 |
|
|
Battery Life |
| |
400 hours typical
without backlight |
|
|
DC millivolts |
|
Range: |
600.0 mV |
|
Resolution: |
0.1 mV |
|
Accuracy: |
± ([% of reading] +
[counts]): 0.5% + 2 |
|
|
DC volts |
|
Range/Resolution: |
6.000V / 0.001V |
|
Range/Resolution: |
60.00V / 0.01V |
|
Range/Resolution: |
600.00V / 0.1V |
|
Accuracy: |
± ([% of reading] +
[counts]): 0.5% + 2 |
|
|
Auto volts |
|
Range: |
600.0 V |
|
Resolution: |
0.1 V |
|
Accuracy: |
1.0 % + 3 (dc, 45 Hz
to 500 Hz)2.0 % + 3
(500 Hz to 1 kHz) |
|
|
AC millivolts true-rms |
|
Range: |
600.0 mV |
|
Resolution: |
0.1 mV |
|
Accuracy: |
1.0 % + 3 (dc, 45 Hz
to 500 Hz)2.0 % + 3
(500 Hz to 1 kHz) |
|
|
AC volts true-rms |
|
Range/Resolution: |
6.000 V / 0.001 V |
|
Range/Resolution: |
60.00 V / 0.01 V |
|
Range/Resolution: |
600.0 V / 0.1 V |
|
Accuracy: |
1.0 % + 3 (dc, 45 Hz
to 500 Hz)2.0 % + 3
(500 Hz to 1 kHz) |
|
|
Continuity |
|
Range: |
600 Ω |
|
Resolution: |
1 Ω |
|
Accuracy: |
Beeper on < 20 Ω,
off > 250 Ω
Detects opens or shorts of 500 μs or longer. |
|
|
Ohms |
|
Range/Resolution: |
600.0 Ω / 0.1 Ω |
|
Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
|
Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
|
Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
|
Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
|
Accuracy: |
0.9 % + 1 |
|
Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
|
Accuracy: |
5 % + 2 |
|
|
Diode Test |
|
Range/Resolution: |
2.00 V / 0.001 V |
|
Accuracy: |
0.9% + 2 |
|
|
Capacitance |
|
Range/Resolution: |
1000 nF / 1 nF |
|
Range/Resolution: |
10.00 µF / 0.01 µF |
|
Range/Resolution: |
100.0 µF / 0.1 µF |
|
Range/Resolution: |
9999 µF / 1 µF |
|
Range/Resolution: |
100 µF to 1000 µF |
|
Accuracy: |
1.9% + 2 |
|
Range/Resolution: |
> 1000 µF |
|
Accuracy: |
5% + 20% |
|
|
Lo-Z Capacitance |
|
Range: |
1 nF to 500 µF |
|
Accuracy: |
10% + 2 typical |
|
|
AC amps true-rms (45 Hz
to 500Hz) |
|
Range/Resolution: |
6.000 A / 0.001 A |
|
Range/Resolution: |
10.00 A / 0.01 A |
|
Accuracy: |
1.5% + 3 |
| |
20 A overload for
30-seconds max |
|
|
DC amps |
|
Range/Resolution: |
6.000 A / 0.001 A |
|
Range/Resolution: |
10.00 A / 0.01 A |
|
Accuracy: |
1.0% + 3 |
| |
20 A overload for
30-seconds max |
|
|
Hz (V or A input) |
|
Range/Resolution: |
99.99 Hz / 0.01 Hz |
|
Range/Resolution: |
999.9 Hz / 0.01 Hz |
|
Range/Resolution: |
9.999 kHz / 0.001
kHz |
|
Range/Resolution: |
50 kHz / 0.01 kHz |
|
Accuracy: |
0.1% + 2 |
|
|
Size |
| |
167 x 84 x 46 mm
(6.57" x 3.31" x 1.82") |
|
|
Weight |
|
|
Warranty |
|