Fluke
87V Ex
Intrinsically Safe
True RMS Digital Multimeter

Intrinsically safe version of the world’s
most popular multimeter

|
 |
With its high performance, accuracy and motor drive
compatibility, the Fluke 87V
is the most popular industrial multimeter in the
world. Now Fluke has introduced a new intrinsically
safe version – the 87V Ex – for measurements in and
around hazardous areas.
The new Fluke 87V Ex has all the measurement and
troubleshooting functions of the proven Fluke 87V.
Unlike most other ATEX-certified tools, it can be
used both inside and outside the hazardous zone (ATEX
Zones 1 & 2) without compromising performance or
compliance. So there’s no need to carry different
tools for use inside or outside the hazardous zones.
It also has a built-in thermometer with TC probe,
further reducing the technician's tool count.
|

|
Fluke 87V Ex Features
-
ATEX safety rating for use in Ex-zone
1 and zone 2.
-
CAT IV 600 V electrical safety
rating.
-
Unique function for accurate voltage
and frequency measurements on variable speed motor drives (VSD’s).
-
Large display with bright, two-level
backlight makes the 87V Ex easy to read in all lighting
environments.
-
Built-in thermometer (probe
included).
-
True-rms ac voltage and current for
accurate measurements on non-linear signals.
-
4-1/2 digit mode for precise
measurements (20,000 counts).
-
Measure up to 1000V and 10A (AC/DC).
Frequency to 200 kHz and % duty cycle.
-
Resistance, continuity and diode
test.
-
10,000 μF capacitance range for
components and motor caps.
-
Min/Max-Average and Peak capture to
record transients and variations automatically.
-
Relative mode to remove test lead
interference on resistance measurements.
-
Auto and manual ranging for maximum
flexibility.
-
Analog bargraph for fast changing or
unstable signals.
Safety Ratings
-
ATEX safety rating: II 2 G EEx ia IIC
T4
-
Electrical safety rating: EN61010-1
CAT IV 600 V and CAT III, 1000 V
|
 |
 |

Fluke 87V EX
Intrinsically Safe Multimeter Specifications
|
|
Operating Specifications |
|
Voltage DC |
|
Maximum Voltage: |
1000V |
|
Accuracy: |
±(0.05%+1) |
|
Maximum Resolution: |
10 µV |
|
|
Voltage AC, True RMS |
|
Maximum Voltage: |
1000V |
|
Accuracy: |
±(0.7%+2) |
|
AC Bandwidth |
20 kHz |
|
Maximum Resolution: |
10
µV |
|
|
Current DC |
|
Maximum Amps: |
10A (20A for 30
seconds maximum) |
|
Amps Accuracy: |
±(0.2%+2) |
|
Maximum Resolution: |
0.01µA |
|
|
Current AC, True RMS |
|
Maximum Amps: |
10A (20A for 30
seconds maximum) |
|
Amps Accuracy: |
±(1.0%+2) |
|
Maximum Resolution: |
0.1 µA |
|
|
Resistance |
|
Maximum Resistance: |
50 MΩ |
|
Accuracy: |
±(0.2%+1) |
|
Maximum Resolution: |
0.01Ω |
|
|
Capacitance |
|
Maximum Capacitance |
9,999 µF |
|
Accuracy |
±(1%+2) |
|
Maximum Resolution |
0.001 nF |
|
|
Frequency |
|
Maximum Frequency |
200 kHz |
|
Accuracy |
±(0.005%+1) |
|
Maximum Resolution |
0.001 Hz |
|
|
Duty Cycle |
|
Maximum Duty Cycle |
99.90% |
|
Accuracy |
±(0.2% per kHz
+0.1%) |
|
Maximum Resolution |
0.10% |
|
|
Temperature |
|
Range: |
-200.0°C to 1090°C
(-328°F to 1994°F)
excluding probe |
|
|
80 BK Temperature Probe |
|
Range: |
-40.0°C to 260°C
(-40° to 500°) |
|
Accuracy: |
2.2°C or 2%, whichever is greater |
|
|
Conductance |
|
Maximum Conductance |
60.00 nS |
|
Accuracy |
±(1.0%+10) |
|
Maximum Resolution |
0.001 nS |
|
|
Diode |
| Range |
Range 3V |
|
Resolution: |
1 mV |
|
Accuracy: |
± (2% + 1) |
|
|
Duty Cycle Range |
|
Accuracy: |
Within ± (0.2% per
kHz + 0.1%) |
|
|
|
Restrictions in Ex
Hazardous Area |
|
Maximum Voltage |
65 V |
|
Maximum Current |
5 A |
|
|
Environmental Specifications |
|
Operating temperature
|
|
|
Storage temperature
|
|
|
Humidity (without
condensation) |
| |
0% - 80% (0°C -
35°C) |
| |
0% - 70% (35°C -
55°C) |
|
|
Operating Altitude |
|
|
Safety Specifications |
|
Overvoltage category |
| |
EN 61010-1 to 1000 V
CAT III, 600V CAT IV |
|
|
Agency Approvals |
|
|
ATEX Certification |
|
|
Agency Approvals |
|
|
Mechanical & General
Specifications |
|
Size |
| |
201 x 98 x 52 mm
with holster |
|
|
Weight |
| |
355 g (12.5 oz) with
holster and flex stand, |
|
|
Display |
|
Digital: |
6000 counts updates
4/sec. |
| |
19,999 counts in high-resolution mode.) |
|
Analog: |
32 segments, updates
40/sec. |
|
Frequency: |
19,999 counts,
updates 3/sec at > 10 Hz. |
|
|
Warranty |
|
|
Battery life |
|
Alkaline: |
~400 hours typical,
without backlight |
|
|
Shock |
| |
1 Meter drop per IEC
61010-1:2001 |
|
|
Vibration |
| |
Per MIL-PRF-28800
for a Class 2 instrument |
|
|

Fluke 87V Ex Model
Dscriptions
|
|
Model Name |
Included Items |
|
Fluke 87V Ex |
- TL75 Test Leads
- AC72 Alligator Clips
- Red Holster
- 9V Battery (installed)
- Getting Started Manual
- CD with Detailed Manual
|

|
Fluke 80 Series
Accessories
|
|