Fluke
83V & 87V
Series V Digital Multimeters

Accuracy and diagnostic functions for maximum
industrial productivity

|
The new Fluke 87V multimeter has
improved measurement functions, trouble-shooting features,
resolution and accuracy to solve more problems on motor drives, in
plant automation, power distribution and electro-mechanical
equipment. The New 80
Series consists on the following models:
-
Fluke 83V Industrial DMM
-
Fluke 87V True RMS Industrial DMM
-
Fluke 87 V/E2 Industrial Electricians Combo Kit
-
Fluke 87 V/AEK Advanced Electronic Combo Kit
-
Fluke 87V Ex Intrinsically Safe True RMS DMM
The 80
Series V operates very similar to the classic 80 series, but with
more problem solving power, safety, convenience and impact
protection.
The new 80
Series V are independently tested to comply with the 2nd edition of
ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can
withstand impulses in excess of 8,000V and reduce risks related to
surges and spikes. |
 |
 |

Features for maximum
productivity
|
|
 |
- Unique function
for accurate voltage and frequency measurements
on adjustable speed motor drives and other
electrically noisy equipment (87V).
- Built-in
thermometer conveniently allows you to take
temperature readings without having to carry a
separate instrument (87V).
- Optional
magnetic hanger for easy set-up and viewing
while freeing your hands for other tasks.
- Large digit
display with bright, two-level backlight makes
the 80- Series V significantly easier to read
than older models.
|

Electrical safety
All inputs are protected to the 2nd edition of ANSI/ISA
S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They
can withstand impulses in excess of 8.000 V and reduce risks
related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
|
Until now, there hasn't
been a multimeter able to accurately measure
adjustable speed drives. But the new Fluke 87V is
designed specifically to handle these complex
signals. Think of the potential productivity you'll
gain by taking the guesswork out of drive system
troubleshooting.
- Unique function
for accurate measurement of noisy pulse-width
modulated AC voltage. Measures correctly at the ASD and at the motor terminals.
- Accurately
measure the frequency (motor speed). Frequency
measurement are not affected by the ASDs carrier
frequency.
- Measure AC
current with an optional current clamp accessory.
- Compare reading
from the 87V with the display on the ASD.
- Special
shielding blocks high frequency, high-energy
noise generated by large drive systems.
|
 |
 |
|
 |
|
Complex
PWM drive signals are no problem for the Fluke 87V.
|
|
Pulse-width modulated detail of 50 Hz motor drive output
voltage. 1000 V, 50 µs can cause erratic behavior in
some test equipment. |

Fluke 80 Series
V Digital Multimeter Selection
|
|
True-rms ac voltage
and current for accurate measurements on non
linear signals |
|
• |
|
Selectable filter for
accurate voltage and frequency measurements on
motor drives |
|
• |
|
0.05 % dc accuracy
|
|
• |
|
6000 counts, 3-3/4
digits |
• |
• |
|
4-1/2 digit mode for
precise measurements (20,000 counts)
|
|
• |
|
Measure up to 1000 V
ac and dc |
• |
• |
|
Measure up to 10 A,
20 A for up to 30 seconds |
• |
• |
|
Built in thermometer
lets you carry one less tool (TC probe included)
|
|
• |
|
Frequency to 200 kHz
and % duty cycle |
• |
• |
|
Resistance,
continuity and diode test |
• |
• |
|
10,000 µF capacitance
range for components and motor caps
|
• |
• |
|
Min/Max-Average
recording with Min/Max Alert to capture
variations automatically |
• |
• |
|
Peak capture to
record transients as fast as 250 µs
|
• |
• |
|
Relative mode to
remove test lead interference from low ohms
measurements |
• |
• |
|
Auto and manual
ranging for maximum flexibility
|
• |
• |
|
Touch Hold to capture
stable readings avoiding noisy signals
|
• |
• |
|
Large display digits
and two-level bright white backlight for
increased visibility |
• |
• |
|
Analog bargraph for
fast changing or unstable signals
|
• |
• |
|
Input Alert provides
audible warning against wrong use of input jacks
|
• |
• |
|
Improved selectable
sleep mode for long battery life
|
• |
• |
|
Access door for fast
battery changes without breaking the calibration
seal |
• |
• |
|
"Classic" design with
new removable holster with built in test lead
and probe storage |
• |
• |
|
Lifetime warranty
|
• |
• |
|
|

Fluke 80 Series V
Multimeter Specifications
|
|
Operating Specifications |
|
Voltage DC |
|
Maximum Voltage: |
1000V |
|
Accuracy: |
Fluke 83 V:
±(0.1%+1) |
| |
Fluke 87 V:
±(0.05%+1) |
|
Maximum Resolution: |
Fluke 83 V: 100 µV |
| |
Fluke 87 V: 10 µV |
|
|
Voltage AC |
|
Maximum Voltage: |
1000V |
|
Accuracy: |
Fluke 83 V:
±(0.5%+2) |
| |
Fluke 87 V:
±(0.7%+2) True RMS |
|
AC Bandwidth |
Fluke 83 V: 5 kHz |
| |
Fluke 87 V: 20 kHz* |
| |
*with low pass
filter; 3 db @ 1 kHz |
|
Maximum Resolution: |
0.1 mV |
|
|
Current DC |
|
Maximum Amps: |
10A (20 A for 30
seconds maximum) |
|
Amps Accuracy: |
Fluke 83 V:
±(0.4%+2) |
| |
Fluke 87 V:
±(0.2%+2) |
|
Maximum Resolution: |
Fluke 83 V: 0.01 mA |
| |
Fluke 87 V: 0.01 µA |
|
|
Current AC |
|
Maximum Amps: |
10A (20A for 30
seconds maximum) |
|
Amps Accuracy: |
Fluke 83 V:
±(1.2%+2) |
| |
Fluke 87 V:
±(1.0%+2) True RMS |
|
Maximum Resolution: |
0.1 µA |
|
|
Resistance |
|
Maximum Resistance: |
50 MΩ |
|
Accuracy: |
Fluke 83 V:
±(0.4%+1) |
| |
Fluke 87 V:
±(0.2%+1) |
|
Maximum Resolution: |
0.1Ω |
|
|
Capacitance |
|
Maximum Capacitance |
9,999 µF |
|
Accuracy |
±(1%+2) |
|
Maximum Resolution |
0.01 nF |
|
|
Frequency |
|
Maximum Frequency |
200 kHz |
|
Accuracy |
±(0.005%+1) |
|
Maximum Resolution |
0.01 Hz |
|
|
Duty Cycle |
|
Maximum Duty Cycle |
99.9% |
|
Accuracy |
±(0.2% per khz
+0.1%) |
|
Maximum Resolution |
0.1% |
|
|
Temperature Measurement |
|
Fluke 83V, 87 V/E: |
-200.0°C - 1090°C |
| |
-328.0°F - 1994.0°F |
| |
excluding probe |
|
|
80 BK Temperature Probe |
|
Range |
-40.0°C to 260°C
(-40.0°F - 500°F) |
|
Accuracy |
2.2°C or 2%, whichever is greater |
|
|
Conductance |
|
Maximum Conductance |
60.00 nS |
|
Accuracy |
±(1.0%+10) |
|
Maximum Resolution |
0.01 nS |
|
|
Diode |
|
Range |
3 V |
|
Resolution: |
1 mV |
|
Accuracy: |
± (2% + 1) |
|
|
Duty Cycle Range |
|
Accuracy: |
Within ± (0.2% per
kHz + 0.1 %) |
|
|
Environmental Specifications |
|
Operating temperature
|
|
|
Storage temperature
|
|
|
Humidity (without
condensation) |
| |
0% - 90% (0°C -
35°C) |
| |
0% - 70% (35°C -
55°C) |
|
|
Operating Altitude |
|
|
Safety Specifications |
|
Overvoltage category |
| |
EN 61010-1 to 1000 V
CAT III, 600V CAT IV |
|
|
Agency Approvals |
|
|
Mechanical & General
Specifications |
|
Size |
| |
201 x 98 x 52 mm
(with holster) |
|
|
Weight |
| |
355 g, 624 g with
holster and flex stand, |
|
|
Display |
|
Digital: |
6000 counts updates
4/sec. |
| |
(Model 87 also has
19,999 counts in high-resolution mode.) |
|
Analog: |
32 segments, updates
40/sec. |
|
Frequency: |
19,999 counts,
updates 3/sec at > 10 Hz. |
|
|
Warranty |
|
|
Battery life |
|
Alkaline: |
~400 hours typical,
without backlight |
|
|
Shock |
| |
1 Meter drop per IEC
61010-1:2001 |
|
|
Vibration |
| |
Per MIL-PRF-28800
for a Class 2 instrument |
|
|

Fluke 80 Series Models &
Descriptions
|
|
Model Name |
Included Items |
|
Fluke 83V |
- TL75 test leads
- AC72 Alligator Clips
- Holster
- 9V battery (installed)
- Getting Started Manual
- CD with detailed manual
|
|
Fluke 87V |
- TL75 test leads
- AC72 Alligator Clips
- Holster
- 9V battery (installed)
- Getting Started Manual
- CD with detailed manual
- 80BK temperature probe
|
|
Fluke 87 V/E |
- 87V Multimeter
- TL224 silicone test
leads
- AC220 long reach
alligator clips
- TP238 test probes
- magnet & strap
- 80BK temperature probe
- holster
- 9V battery (installed)
- Getting Started Manual
- CD with detailed manual
|
|
Related Products |