Navigation:
Home >
Products >
Instruments >
Field Service
Instruments >
Clamp-Style Meters & Current Clamps
Amprobe ACD-10 TRMS-PLUS
True RMS 600A Clamp-On
Multimeter

True RMS clamp-on multimeter for AC & DC voltage to
600V,
AC current to 600A, plus ohms, capacitance & frequency.

Description
Amprobe’s ACD-10 TRMS-PLUS
meter offer thinner jaws over standard clamp meters, allowing access
to tight measurement areas and still accommodating conductors up to
25 mm. Both meters also measure Capacitance and Frequency. Frequency
is measured by either jaws or test leads. Very versatile clamp
multimeters. True RMS version for noisy measurement environments for
a more accurate reading.
|
 |
|
Features
- True RMS (TRMS) voltage &
current measurement
- AC & DC Voltage to 600V
- AC Current to 600A
- Thin Jaws only 10 mm (0.4”)
thick
- Resistance to 40 MΩ
- Continuity Buzzer
- Capacitance to 3000 µF
- Frequency measurement
- Inrush current
- Hold & Maximum reading functions
- Accommodates conductors up to 26 mm (1.02”) in diameter
- Auto ranging
- Auto power off
- Rubber over-molded case
- Overload protected
- Included Accessories: Test
leads, battery installed, soft carrying pouch, users manual
- Wide choice of
Amprobe multimeter
accessories
|

|
DC Voltage Ranges |
400.0 mV, 4.000, 40.00, 400.0 V, 600 V |
|
DC Voltage Accuracy |
± 0.5% rdg ± 3 digits (±
1.0% rdg ± 4 digits on 600V scale) |
|
AC Voltage Ranges |
4.000, 40.00, 400.0 V, 600 V |
|
AC Voltage Accuracy |
± 1.5% rdg ± 5 digits (±
2.0% rdg ± 5 digit on 600V scale) |
|
AC Crest Factor |
< 1.75 : 1 at full scale limited to
fundamental and harmonics, that fall within the meter
specified AC bandwidth for non-sinusoidal waveforms. |
|
Input Impedance |
10 MΩ |
|
Transient Protection |
6.5 kV (1.2 / 50 μs surge) |
|
AC Current (clamp-on) |
40.00, 400.0, 600 A |
|
True RMS Sensing |
10% to 200% of range |
|
Overload Protection |
600A rms continuous |
|
Resistance Ranges |
400.0 Ω, 4.000, 40.00, 400.0 kΩ, 4.000 MΩ,
40.00 MΩ |
|
Frequency Ranges |
0 Hz to 100 kHz (depending on signal
type) |
|
Capacitance Ranges |
500.0 nF, 5.000 μF, 50.00 μF, 500.0 μF,
3000 μF |
|
Diode Test |
< 1.6 VDC @ 0.25 mA |
|
Audible Continuity Test |
Between 10 Ω and 120 Ω |
|
Display |
3-3/4 digit (4000 count) LCD
display |
|
Update Rate |
3 per second |
|
Polarity |
Automatic |
|
Operating Temperature |
0°C to 40°C |
|
Relative Humidity |
< 80% RH up to 31°C decreasing to 50% RH at
40°C |
|
Altitude |
Operation below 2000 m. Indoor use. |
|
Storage Temperature |
-20°C to 60°C, < 80% RH (with battery
removed) |
|
Low Battery |
Below approx. 2.4V |
|
Power Supply |
3V coin battery IEC-CR2 |
|
Power Consumption |
2.8 mA typical, except 3.3 mA typical for
ACA function |
|
Auto Power Off |
After being idle for 30 minutes |
|
Max Conductor Diameter |
26 mm (1 inch) |
|
Special Features |
30ms Max Hold; Data Hold; Relative Zero
mode |
|
Dimensions |
190 x 63 x 32 mm (7.4 x 2.5 x 1.3 in) |
|
Weight |
139 gm |
|
Safety |
Meets EN61010-2-032,
UL61010B-2-032, IEC61010-1 2nd Ed., EN61010-1 2nd Ed.,
UL61010-1 2nd Ed. CAT III-600 Volts ac & dc; Pollution
degree : 2 |
|
Related Products |
ACD-10 PLUS 600A Clamp-On Multimeter |

| Included Accessories

Test leads, battery
installed, soft carrying pouch, users manual. |
|