LIDA® ONE
The Single Anode
from ELTECH

ONE anode, ONE cable. It's that
simple: 1" x 45"
1" x
60"
1" x 90"

Overview
The ELTECH LIDA®
ONE anode is the newest in the family of mixed metal oxide anode
products specifically tailored to the cathodic protection of buried structures.
Designed for installations where a single anode on a string is preferred
for groundbeds with widely varying soil resistivities, the mixed metal
oxide coating is specially formulated for use in a carbonaceous backfill.
LIDA® ONE is
a 1" diameter titanium tube with a precious metal oxide coating.
This mixed metal oxide is a crystalline, electrically-conductive coating
that activates the titanium and enables it to function as an anode. When
applied on titanium, the coating has an extremely low consumption rate,
measured in terms of milligrams per year. As a result of this low consumption
rate, the tubular dimensions remain nearly constant during the design
life of the anode - providing a consistently low resistance anode.
By increasing the
length of our tubular anode, yet reducing total current output, ELTECH
Systems Corporation has created another reliable mixed metal oxide anode
product line with even greater cost savings over competitive anode technologies.
As with all of ELTECH's mixed metal oxide tubular anodes, the combination
of a tough and lightweight product, its ease of handling and installation,
the superior mechanical connection, and our five year, no hassle warranty,
makes LIDA® ONE the ONE anode for unparalleled CP performance.

The
"Single Anode" Concept from ELTECH Systems Corporation:
ONE anode, ONE cable.
It's that simple.
|
 |
Features
- Designed to be
used as a single anode.
- Durable - no breakage
or damage while getting it to the job site.
- Mixed metal oxide
coating specially formulated for maximum performance in coke backfill.
- Special crimped
moisture seal to prevent damage to electrical connection.
- No lead ... no
epoxy potting compounds.
- Five-Year Product
Warranty.
|

|
Characteristics
LIDA® ONE Anodes
(in coke backfill)
|
Anode
|
Nominal
Rated Current (amps)
|
Weight
(lbs)
|
| |
10
yrs.
|
15
yrs.
|
20
yrs.
|
non-weighted
|
weighted
|
|
1"
X 45"
|
5.0
|
4.0
|
3.4
|
1.4
|
4.0
|
|
1"
X 60"
|
6.6
|
5.3
|
4.5
|
1.6
|
6.0
|
|
1"
X 90"
|
9.9
|
7.9
|
6.8
|
2.0
|
9.0
|
LIDA® ONE has
been designed to be used with a wide variety of cable types and sizes.
Whether economics are your primary consideration, or a severe groundbed
operating environment is anticipated, we provide LIDA® ONE with the
cable that best meets your requirements.
LIDA®
ONE Cable Types
| Type |
Wire
Size |
|
Nominal |
|
Weight |
Length |
|
kg/m |
lbs/ft |
|
Outer
Jacket |
Inner
Jacket |
Maximum
Current
Output |
| HMWPE |
|
|
|
|
|
PVDF/
HMWPE |
|
|
|
|
|
|
| |
 |
LIDA ONE has been designed to be used with a wide variety of cable types
and sizes. Whether economics are your primary consideration, or a severe groundbed
operating environment is anticipated, Farwest provides LIDA ONE with the cable that best meets
your requirements.
Regardless of the type of current anode used, proper groundbed design is paramount to
optimum, low resistance performance. Farwest recommends the use of quality,
conductive, carbonaceous backfill, a vent pipe, and centralizers, suitable cable, and good
design practices and understanding.
|
|
|
|