Navigation:
Home >
Products >
Impressed Current Anodes >
Anodes
- Mixed Metal Oxide
De Nora LIDA® Tubular
Anodes

Applications
Groundbeds
- Deep
- Shallow
- Vertical
- Horizontal
- Open Hole
Marine
- Sea Water
- Brackish Water
- Mud
Fresh Water
|

|
|

Features
|
- Multi-anode conductor
- Lightweight / durable
- High current output
|
- Patented crimp
connections
- Dimensionally
stable
|

Benefits
- Dramatically
reduces cable costs
- Reduced handling
and installation costs
- Lower cost per amp
- Guaranteed
electrical contract and moisture seal integrity
- Consistently low
resistance anode
|

Description
LIDA®
anodes utilize an innovative and patented design: a titanium base with
a mixed metal oxide conductive coating. This coating forms a solid solution
with the titanium substrate and is an excellent electronic conductor.
The mixed oxides are formed
on the surface through a process of thermal decomposition, creating an oxide
film which is typically anhydrous and almost insoluble in acids. Thermal control
of this process causes the mixed oxides to recrystallize, further increasing
their chemical stability.
These anodes are often referred to as composite anodes. Physically, this term
refers to a ductile, corrosion resistant base metal covered with the highly
conductive stable film described above. The base metal, titanium, provides the
required toughness for the system. The titanium substrate is classified as a
"valve metal" or film forming metal. Such metals in their natural
state are protected by thin, self-healing, tightly adherent oxide films which
are acid resistant and resist the passage of current in the anodic direction.
Thus, if an attempt is made to operate a valve metal as an anode, it is necessary
to raise the potential of the valve metal surface to a high value in order to
pass significant current through the anode.
Then, in order to use titanium as a realistic impressed current anode, the growth
of the insulating oxide must be prevented. The electro-conductive film applied
to the surface of titanium satisfies this requirement and permits the flow of
electrical current at a low and steady voltage.
The wear rate of the LIDA® anodes is extremely low and uniform. The thickness
of the mixed oxide film decreases linearly with time at all points on the surface.
The wear rate of the anode is between 3 and 6 milligrams/ampere-year, and is
constant over all current densities in general or frequent use.
De Nora LIDA® anodes are resistant to abrasion with a hardness of approximately
6 on the Mohs scale. De Nora mixed metal oxide anodes are available for soil,
fresh water, mud and seawater environmently. These anode systems function reliably
in cathodic protection systems in the soil as deep well or shallow groundbeds
as well as in natural water applications.
LIDA® anodes
for soil application are available in two lengths, and two diameters, to meet
a range of current output requirements: 50 and 100 cm (20 and 40 inch) and two
diameters, 1.6 and 2.5 cm (.64 and 1.0 inch).
They are available as a single-unit assembly, or as a multi-unit assembly on
a single cable. De Nora wire or tubular anodes are also available as canistered
anodes, surrounded by carbonaeous backfill to minimize installation time and
handling on site. De Nora mixed metal oxide anodes are also available in wire,
rod, mesh, ribbon, and disc form for a variety of impressed current CP applications.
According to OSHA Regulations, the precious metal coating and the substrate to which it is applied constitute and "Article." An "Article" is defined as being a manufactured item which is formed with specific shape or design during manufacture which has end-use function dependent in whole or in part upon its shape or design during end-use and which does not release or otherwise result in exposure to a hazardous chemical under normal conditions of use.
An "Article" is specifically excluded from the scope of the Hazard Communication Rule. As such, no MSDS would be required for sale of coated substrates.
|

|
Reliability |
|
In choosing the De Nora LIDA® tubular anode, you have selected the most durable and reliable
product in the industry for your cathodic protection needs. De
Nora LIDA®
tubular anode strings are backed by a five-year, no hassle warranty. Design, assembly
and installation factors have been carefully considered so that your
time and costs are minimized as much as possible.
|
|
Savings |
Ease of Installation |
- In many cases, De
Nora LIDA® mixed metal oxide tubular anodes offer savings
of 15 - 35% over competitive anodes on an installed cost basis.
|
- De Nora LIDA® anode-cable assemblies are easy to handle, transport and install
because of their unique flexibility. It makes your job on-site easier
as well.
|
|
Quality Assurance |
From the application
of the coating to the design of the shipping crate, De Nora's attention
to quality sets these anodes apart. The coating undergoes
stringent quality control examination by SEP, X-ray and adhesion test
methods throughout the coating process to assure proper thickness and
application. Anode strings are
100%t tested for the quality of electrical conductivity and integrity
of the seal. Personal attention
to each detail of the quality control process assures you a superior,
reliable product. De Nora offers one of the best anode warranties
available.
|
|
Special Services |
Farwest offers groundbed
design services to customers. Our experienced personnel can assist
you in designing the most efficient, cost-effective approach for many
unique applications.
|

|
LIDA Crimp |
|

Anode to cable sealing
at each end
- Both ends of the tubular
anode are sealed over the insulated cable by applying 50 tons of hydraulic
pressure. This crimping process eliminates the need for mastic or resin
sealants.
|

Anode-to-cable electrical
connection at center
- Electrical connection
between the tubular anode and the power cable wire is achieved by sliding
the tube onto the cable and crimping a section of the tube at mid-length
around a stripped portion of the cable.
|
Many impressed
current anodes are connected to the cable with resin-based seals which
may develop cracks or lose adhesion to the cable or anode. Moisture
penetration also may occur, resulting in loss of electrical contact. De
Nora LIDA® anodes
are connected with a special crimping process which improves the life
of the tubular anode system. On the surface, the
crimp on the ends and in the middle appear the same. Yet they serve different
purposes and are made differently. The center crimp makes electrical contact
with the cable while the end crimps form a moisture-resistant seal.
|

Tubular Anode
Dimensions
| Anode |
Diameter |
Length |
Weight |
Surface
Area |
| 2.5/50 |
1.00"
2.5 cm |
19.7"
50 cm |
0.40 lbs
0.18 kg |
0.42 ft2
0.039 m2 |
| 2.5/100 |
1.00"
2.5 cm |
39.4"
100 cm |
0.77 lbs
0.35 kg |
0.84 ft2
0.079 m2 |

Tubular
Anode Cable Selection
De
Nora recommends dual-insulated cable, such as PVDF/HMWPE
cable for use where anodes operate in groundbeds high in chlorides - resulting
in chlorines gas generation. Where chlorides are not anticipated, such as shallow vertical and horizontal
surface beds, an economical cable choice is HMWPE. The high current capacity (150 amps) and flexibility of the Exane Rig cable
makes it ideal for seawater applications.
|
LIDA®
Tubular Cable Recommendations
| Type |
Wire
Size |
|
Nominal |
|
Weight Length |
| kg/m |
lbs/ft |
|
Outer
Jacket |
Inner
Jacket |
Max
Current Output |
Features |
| HMWPE |
#8
#6 |
|
|
|
|
Economical |
PVDF/
HMWPE |
#8
#6 |
|
|
|
|
Chlorine-resistant |
| Exane Rig
Cable |
4/0 |
|
Exane irradiated
cross-linked
polyolefin |
|
|
|
Highly Flexible
High Current Capacity |

MAXIMUM RATED
CURRENT OUTPUT
as a function of DESIGN LIFETIME

De Nora LIDA®
Tubular Anode Specifications
|
Application
|
Anode
Type
|
Life
|
Maximum
Rated
Output
|
|
Temp
|
Amps
|
Temp
|
Amps
|
| Coke
(Soil) |
FW/ST
2.5/100
|
20
|
|
11.0
|
|
|
|
FW/ST
2.5/50
|
20
|
|
5.5
|
|
|
| Fresh
Water |
FW/ST
2.5/100
|
20
|
above
5° C
(40° F)
|
13.5
|
below
5° C
(40° F)
|
9.5
|
|
FW/ST
2.5/50
|
20
|
6.8
|
4.8
|
| Brackish
Water |
FW/ST
2.5/100
|
15
|
above
5° C
(40° F)
|
20
|
below
5° C
(40° F)
|
14.0
|
|
FW/ST
2.5/50
|
15
|
10
|
7.0
|
Mud
Fresh or
Brackish |
MT/ST
2.5/100
|
15
|
above
5° C
(40° F)
|
11.2
|
below
5° C
(40° F)
|
7.8
|
|
MT/ST
2.5/50
|
15
|
5.6
|
3.9
|
| Seawater |
SWT
2.5/100
|
15
|
above
10° C
(50° F)
|
37.5
|
below
10° C
(50° F)
|
26.3
|
|
SWT
2.5/50
|
15
|
19.0
|
13.3
|
| Mud
- Saline |
MT
2.5/100
|
15
|
above
10° C
(50° F)
|
18.8
|
below
10° C
(50° F)
|
13.2
|
|
MT
2.5/100
|
15
|
9.5
|
6.7
|

De
Nora LIDA®
Advantage
De Nora LIDA Crimp
Many impressed current anodes are connected to the cable
with resin-based seals which may develop cracks or lose adhesion to the cable or the
anode. Moisture penetration also may occur, resulting in loss of electrical contact.
De Nora LIDA anodes are connected with a special crimping
process which improves the life of the tubular anode system. On the surface, the crimp on
the ends and in the middle appear the same. Yet they serve different purposes and are made
differently. The center crimp makes electrical contact with the cable while the end crimps
form a moisture-resistant seal.
Electrical connection between the tubular anode and the
power cable wire is achieved by sliding the tube onto the cable and crimping a section of
the tube at mid-length around a stripped portion of the cable.
Both ends of the tubular anode are sealed over the
insulated cable by applying 50 tons of hydraulic pressure. The crimping process eliminates
the need for mastic or resin sealants.
Reliability
In choosing the De Nora LIDA tubular anode,
you have selected the most durable and reliable product in the industry
for your cathodic protection needs. De Nora LIDA tubular anode strings are backed by a five-year, no hassle
warranty. Design, assembly and installation factors have been carefully considered so that
your time and costs are minimized as much as possible.
Savings
In many cases, De Nora LIDA mixed metal oxide tubular anodes
offer savings of 15-35% over competitive anodes on an installed cost basis.
Ease of Installation
The De Nora LIDA anode-cable assemblies are easy to handle,
transport and install because of their unique flexibility. It makes your job on-site
easier as well.
Special Services
De Nora offers groundbed design services to our customers.
The company's experienced personnel can assist you in designing the most efficient,
cost-effective approach form many unique applications. De Nora also offers a design
software package which is available at no cost. Customers find it helpful in designing groundbeds in a wide range of applications.
Quality Assurance
From the application of the coating to the design of the
shipping crate, De Nora's attention to quality sets us apart. The coating also undergoes
stringent quality control examination by SEP, X-ray and adhesion test methods throughout
the coating process to assure proper thickness and application.
Anode strings are 100 percent tested for the quality of
electrical conductivity and for integrity of the seal. The leakage test uses helium and a
special detector to confirm the integrity of the seal. Each and every electrical
connection is checked by applying 20 amps and measuring the voltage drop. Our personal
attention to each detail of the quality control process assures you of a superior,
reliable product.
|

|
Tubular
Anode Guidelines for Use
In groundbed design, it
is important to remember that the purpose of the tubular anode is to provide
current to the coke breeze column. Good design of a groundbed begins with first
sizing the diameter and depth of the coke breeze column (active depth).
Parameters important to
consider in the design are:
- Backfill current density.
This value is the groundbed current divided by the surface area of the backfill
column that contacts the soil. In most deep groundbeds, this value should
not exceed 100 - 200 mA/ft2.
- Coke breeze resistivity.
Use a realistic value based on experience in the area or obtain advice from
the supplier.
- Average soil resistivity
- Soil strata makeup.
What is the water table depth ?
- Groundbed current.
- Chemical contact of
groundwater or moisture. Is chloride salt likely to be present ?
Ventralizers
For optimum performance, Ventralizers should be used to assure that the tubular
anodes will be located in the center of the groundbed. The Ventralizer's unique
design further allows the operator to attach the anode to the vent pipe - providing
1" of separation between the anode and vent pipe. Standard sizes are 6", 8"
and 10", suitable for hole sizes ranging from 6" to 12".
Vent Pipes
Vent pipes should be used in all deep groundbeds. The importance of vent pipes
includes.
- Removal of gases generated
downhole.
- Providing a means to
water the hole, if necessary.
- Allowing heat to escape
from the hole.
It is important to keep
the vent pipe clear. Therefore, hole or slit sizes should be smaller than the
smallest particle size of the backfill to keep it from filling the vent pipe.
Backfill
Selection and installation of a high-quality carbonaceous backfill is critical
for proper performance of all types of groundbeds. Backfills should be pumped
from the bottom of the hole and the fill pipe removed.
Backfills for De Nora LIDA®
tubular anodes must have the following characteristics.
| |
Metallurgical Coke |
Petroleum Calcined
Coke |
| Resistivity |
Max. 50 ohm-cm |
Max. 50 ohm-cm |
| Particle Size |
0.1 - 3 mm
(150-5 mesh) |
0.1 - 1 mm
(150-20 mesh) |
| Carbon Content |
Min. 70% |
Min. 90% |
Hole Drilling
- Cleaning
In all groundbeds, regardless of anode types or bed geometry, the hole must
be cleaned prior to installation of anodes, vent pipe and backfill. This
prevents contamination of the backfill, which can cause high resistivity and
short groundbed life.
|

De Nora LIDA® Tubular Anode
Manufacturing & Quality Control
LIDA® tubular anodes are
available for saltwater, soil, fresh water and mud environments. These titanium
activated anodes experience negligible consumption, yet can deliver electrical
output higher than traditional anodes such as graphite, and high silicon/chromium
cast iron. We will focus on how the LIDA® tubular strings are prepared and the
quality control attendant with their manufacture. LIDA®
tubular anodes are available in two diameters, 1.6 and 2.5 cm (0.64 and 1.0
inch). Cables utilized in assembling De Nora LIDA®
strings may consist of the following:
- EPR/CSPE 50: A two layered cable consisting of an ethylene-propylene inner layer and a
chlorosulfonated polyethlene outer layer. The copper cross section is 50
sq. mm (AWG 1 /0). Only for salt water use.
-
EPR/CSPE 16:
As above with a copper cross section of 16 sq. mm (AWG 6). Only for salt water
use.
-
PVDF/Polyolefin:
A two layered cable consisting of a radiation-crosslinked modified PVDF inner
layer and a modified polyolefin outer layer. The copper conductor is AWG 6
or AWG 8.
String
Assembly Procedure
The desired length of cable is pushed through the tubular anode units; each anode
will have an anode-to cable electrical connection at the center of the tubular
element and two sealing connections, one at each end of the activated titanium
tube.
Initially, a section of the cable's sheathing is removed to expose the copper
wire. Two silver-plated copper sleeves are fixed over the copper wire. The cable
is positioned inside the titanium tube, which is uniformly crimped around the
sleeves providing the superior electrical connection. The compression pressure
at the
crimp is rated at 50 tons.
Both ends of the tube are sealed by the same proprietary technique. No potting
or mastic compounds are used in the seals. Copper, iron, or aluminum rings are
interposed between the coated titanium tube and the teeth of the swaging machine
in correspondence with the anode-cable connection and seals. These rings prevent
the formation of micro-cracks in those areas where the titanium is subject to intense
cold-working.
Quality
Assurance
Quality assurance is of top
priority throughout the manufacturing process. Four principal quality control
measures are used on components of the De Nora LIDA® anode
string and its fabrication therein:
1. Acceptability
of the tubular anode
Includes certification of compliance of the titanium substrate and analysis
verifications of the mixed metal oxide coating.
2. Acceptability of
the power cable
The cable manufacturer must provide complete certification on all electrical
and physical
specifications required by De Nora for LIDA® string manufacture.
3. Electrical continuity
between cable and anode
The electrical continuity between the copper conductor in the power cable
and the anode is determined. The anode-cable resistance at the connection
must be less than 0.001 ohm. Tracking records are maintained.
4. Hydraulic sealing
between cable and anode
Hydraulic sealing between the cable insulating material and the tubular anode
must be
verified. This involves a pressurized helium source and leak detection verified
by means of a mass spectrometer. Tracking records are maintained.
LIDA® strings are custom-assembled
to customer specifications, and delivered ready to install at the jobsite. Anode
centralizers can also be factory-included for further ease of installation. LIDA® tubular strings involve no field splicing
and no heat shrinking. Specialty
constructions are possible when required.
|

Ordering
Information
De Nora LIDA tubular anodes are available from Farwest
Corrosion Control Company. When ordering tubular anodes, please specify the following:
- Anode Type (for example, S.T. 2.5/100).
- Number of anodes per string.
- Center-to-center spacing between anodes along the cable.
- Number of tails (1 or 2).
- Cable tail length (above the top anode).
- Total cable length (sum of lengths of anodes, spaces and
tail).
- Current output.
- Number of centralizers required and hole size.
Ask Farwest about De Noras five-year warranty!
Note: Lida
® is a registered trademarks of De Nora in the USA, Canada and
Mexico.
|
|