Farwest Corrosion
Control Company
 

Home Products Services Contact Us Request Quote Order Online

 
 

 Navigation:  Home > Products > Galvanic Anodes > Anode - Accessories

Adair REDHEAD® & BLUEHEAD®
Heater Treater Anode Mounting Heads


One-piece, high-temperature, flame-retarding, high compression
molded fiberglass anode mounting heads

The REDHEAD®

Built for maximum life in even the harshest of environments, the Redhead® is designed with four integral ribs that insure easy installation, optimal internal alignment and maximum andode stability.

  • The Redhead® is designed with four integral support ribs for skids for easy installation, proper alignment and superior in-flow anode stability.
  • Installs in standard 4-inch (100 mm) Schedule 40 fittings with standard grooved with Victaulic* couplings.
  • Effectively supports anodes of up to 3 inch (76 mm) diameter with a maximum length of 60 inches (1.52 m).
  • Over 15 years of proven service in the field.

The BLUEHEAD ®

Built to the same exacting standards as the Redhead®, the Bluehead® is engineered to withstand the most severe of heater treater environments. Four integral stabilization ribs make for fast and easy installation, optimal alignment and maximum anode stability.

  • The Bluehead® is designed for mounting in (4") four inch (100 mm), Schedule 80 fittings with standard grooved Victaulic* couplings.
  • Effectively supports anodes of up to 3 inch (76 mm) diameter with a maximum length of 60 inches (1.52 m).

General Assembly Instructions

Parts Required for Graphite Anodes

1 Anode, 3” (7.5 cm) maximum diameter
1 RED HEAD or BLUE HEAD
1 ¾” Std. Thread Stud, Cad Plated
1 ¾“ Std. Thread Half-Nut, Cad Plated
1 ¾“ Std. Thread Nut, Cad Plated
1 ¾“ Flat Washer, Cad Plated
Approx. 6 oz (170 gm) hi-temp epoxy or polyester based adhesive mixed to a heavy paste-like consistency.

Installation

  1. Before mixing adhesive, slide Red Head over anode. Do not use force. Red Head should slide smoothly over anode with about 1/32” (0.5-1.0 mm) annular clearance. If Red Head fits tight check anode for rough spots and machine or file as necessary to assure proper fit.
  2. Drill and tap anode approx. 6” (15.5 cm) deep for ¾“ stud. Note: Anode should be impregnated with proper linseed oil at least 24 hours prior to mounting of Red Head.
  3. Screw ¾“ stud tightly into anode. Run half-nut down onto stud.
  4. With acetone, clean stud, nut and anode down approx. 7” (18 cm) from top.
  5. Mix adhesive and apply thin coat onto diameter of anode down approx. 7” (18 cm) from the top. Then apply ¾“ (2 cm) thick amount of adhesive to the top of the anode. Slide Red Head over stud and anode.
  6. Install flat washer and nut and tighten. This will force adhesive down and around anode and also up and around stud and flat washer.
  7. Allow sufficient time for adhesive to cure, then pressure test complete unit with at least 80 psi water pressure.

Parts Required for Metal Anodes

1 Anode, 3” (7.5 cm) maximum diameter
1 RED HEAD or BLUE HEAD
1 ¾“ Std. Thread Nut, Cad Plated
1 ¾“ Flat Washer, Cad Plated
Approx. 6 oz (170 gm) hi-temp epoxy or polyester based adhesive mixed to a heavy paste-like consistency.

Installation

  1. Before mixing adhesive, slide Red Head over anode. Do not use force. Red Head should slide smoothly over anode with about 1/32” (0.5-1.0 mm) annular clearance. If Red Head fits tight check anode for rough spots and machine or file as necessary to assure proper fit.
  2. Mix adhesive and apply thin coat onto diameter of anode down approx. 7” (18 cm) from the top. Then apply ¾“ (2 cm) thick amount of adhesive to the top of the anode. Slide Red Head over stud and anode.
  3. Install flat washer and nut and tighten. This will force adhesive down and around anode and also up and around stud and flat washer.
  4. Allow sufficient time for adhesive to cure, then pressure test complete unit with at least 80 psi water pressure.
     

Cathodic Protection Products & Materials

  

Cathodic Protection Services

 Farwest Engineering
 Farwest Installation

  

Offshore Products Division

 Galvanic CP Systems
 Impressed CP Systems
 Attachment Systems
 Monitoring Equipment

  

Marine Products Division

 Marine ICCP Systems
 Galvanic CP Materials
 Marine Anti-Fouling
 Electrolytic De-Scaling
 Electro-Chlorination
 Marine CP Monitoring
 Galvanic Isolators

  

Corrosion Control Products Company

  

More Farwest
Website Resources

 Farwest News
 Search this Website
 Request Quote
 Order Products Online
 

Home

Products Services Search Request Quote Order Online

Farwest Corrosion Control Company
888-532-7937   (888-5FARWEST)
Complete Cathodic Protection™

Tel: 

 310-532-9524
Fax:  310-532-3934

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.farwestcorrosion.com

© 1996-2011 Farwest Corrosion Control Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956