PosiTector®
6000 Series
Coating Thickness Probes
by DeFelsko

Probe configurations for a wide variety of
materials and coating thicknesses

Positector 6000 Overview |
Gage Selection | Probe
Details | Ordering Chart |
Accessories
|
Overview |
| Selection Note:
F -
for ferrous metals
(example:
FS)
N
- for non-ferrous metals (example:
PosiTector 6000
NS)
FN
- for all metal
substrates (example: PosiTector 6000
FNS) |
 |
Built-in Probes
|
|
Built-in Probe
|
Gage
Models:
|
F1, F2,
F3
|
N1, N2,
N3
|
FN1, FN2,
FN3
|
FT1, FT2, FT3
|
|
|
|
Range:
|
0 - 60 mils |
0 - 250 mils |
|
0 - 1500
µm |
0 - 6 mm |
|
Accuracy*:
|
+
(0.05 mils + 1%) 0
- 2 mils
+ (0.1 mils + 1%) > 2 mils |
+
(0.5 mils + 1%) 0-100 mils
+
(0.5 mil + 3%) > 100 mils |
+
(1 um+1%) 0-50
µm
+
(2 um+1%) > 50
µm |
+
(0.01 mm+1%) 0-2.5 mm
+
(0.01 mm+ 3%) > 2.5 mm |
*Accuracies
are stated as a fixed value plus a percentage of the
gage's actual reading.
 |
|
Regular
|
Probe
Models:
|
FS
|
NS
|
FNS
|
NAS
|
FTS
|
|
|
|
Range:
|
0 - 60 mils |
0 - 25 mils |
0 - 250 mils |
|
0 - 1500 µm |
0 - 625 mm |
0 - 6 mm |
|
Accuracy*:
|
+ (0.05 mils + 1%)
0- 2 mils
+ (0.1 mils + 1%)
> 2 mils |
+ (0.02 mils + 1%)
0-4 mils
+ (0.1 mils + 3%)
> 4 mils |
+ (0.5 mils + 1%)
0-100 mils
+ (0.5 mil + 3%)
> 100 mils |
+ (1 um + 1%)
0 - 50 µm
+ (2 um + 1%)
> 50 µm |
+ (0.5 um + 1%)
0-100 µm
+ (2 um + 3%)
> 100 µm |
+ (0.01 mm + 1%)
0-2.5 mm
+ (0.01 mm + 3%)
> 2.5 mm |
|
*Accuracies are stated as a fixed value plus a
percentage of the gage's actual reading. |
|
90 Regular
|
Probe
Models:
|
FRS
|
NRS
|
FNRS
|
|
|
|
Range:
|
0 - 60 mils |
|
0 - 1500 µm |
|
Accuracy*:
|
+ ( 0.05 mils + 1%)
0 - 2 mils
+ (0.1 mils + 1%) > 2 mils |
+ (1 µm + 1%) 0 - 50
µm
+ (2 µm + 1%) > 50 µm |
| *Accuracies
are stated as a fixed value plus a percentage of the
gage's actual reading. |
|
0
Microprobe |
Probe
Models:
|
F0S
|
N0S
|
  |
Range:
|
0 - 25 mils |
|
0 - 625 um |
|
Accuracy*:
|
+ (0.02 mils + 1%) 0
- 4 mils
+ (0.1 mils + 3%) > 4 mils |
+
(0.5 µm + 1%) 0 - 100 µm
+ (2 µm + 3%) > 100 µm |
|
*Accuracies are stated as a fixed value plus a
percentage of the gage's actual reading. |
|
45 Microprobe
|
Probe
Models:
|
F45S
|
N45S
|
|
|
|
Range:
|
0 - 25 mils |
|
0 - 625 µm |
|
Accuracy*:
|
+ (0.02 mils + 1%) 0
- 4 mils
+ (0.1 mils + 3%) > 4 mils |
+
(0.5 µm + 1%) 0 - 100 µm
+ (2 µm + 3%) > 100 µm |
|
*Accuracies are stated as a fixed value plus a
percentage of the gage's actual reading. |
|
90 Microprobe
|
Probe
Models:
|
F90S
|
N90S
|
|
|
|
Range:
|
0 - 25 mils |
|
0 - 625 µm |
|
Accuracy*:
|
+ (0.02 mils + 1%) 0
- 4 mils
+ (0.1 mils + 3%) > 4 mils |
+
(.5 µm + 1%) 0 - 100 µm
+ (2 µm + 3%) > 100 µm |
|
*Accuracies are stated as a fixed value plus a
percentage of the gage's actual reading. |
Separate High-Range Probes
|
|
High-Range
|
Probe
Models:
|
FNTS
|
FKS
|
NKS
|
|
|
|
Range:
|
0 - 250 mils |
0 - 500 mils |
|
0 - 6 mm |
0 - 13 mm |
|
Accuracy*:
|
+ (0.5 mils + 1%)
0 - 100 mils
+ (0.5 mil + 3%)
> 100 mils |
+ (1 mils + 3%)
0 - 500 mils
+ (0.02 mm + 3%)
0 - 13 mm |
+ (0.01 mm + 1%)
0 - 2.5 mm
+ (0.01 mm + 3%)
> 2.5 mm |
|
*Accuracies are stated as a fixed value plus a
percentage of the gage's actual reading. |
|