7300
By Denso

Moisture Tolerant Pipeline
Liquid Coating

|
Description |
Denso
Protal 7300 is a VOC-free, 100% solids, epoxy coating specially
formulated to coat dry, damp or wet surfaces for galvanic protection and
corrosion control. It is a high-build liquid
coating that is Denso Protal Applicator Pad, Denso Protal 9" Roller, or
brush applied in one coat in the field or shop. |
|
Uses |
For the exterior coating of pipelines, structures or other steel surfaces
that may be wet or damp due to the environment or as a result of atmospheric
condensation. |
|
Features |
•
Can be applied to wet or damp surfaces.
• High build (up to 50 mils in one coat).
• Excellent adhesion to wet and damp surfaces.
• Safe and environmentally friendly.
• Excellent gouge, abrasion and impact resistance. |
|
Surface
Prep |
Prepare surfaces by grit blasting to a clean near white finish, SSPC SP-10/
NACE No. 2. Material for abrasive cleaning shall be the appropriate blend of
grit to produce an angular surface profile of 2.5 - 4 mils (0.063 - 0.10
mm). |
|
Application |
•
Initially stir the base and hardener.
• Add the hardener to base and mix until a constant color is achieved.
(Make sure all sides of container are scraped).
• Pour mixed material onto surface.
• Apply with Denso Protal Applicator Pad, Denso Protal 9" Roller, or brush
(If applying to wet surface, displace water as the coating is applied).
• A wet film thickness gauge shall be used periodically to measure mil
thickness throughout the application process. |
Technical Data
| Properties |
Data |
|
Solids Content |
100% |
|
Base Component - unmixed @ 77°F (25°C)
Viscosity
Color |
Soft gel
White
|
|
Hardener Component - unmixed @ 77°F (25°C)
Viscosity
Color |
Liquid
Black
|
|
Mixed Material - mixed @ 77°F (25°C)
Viscosity
Color |
Light gel
Gray
|
|
Mixing Ratio - (A/B) by Volume |
1.5 parts base, 1 part hardener |
|
Cure Times
Pot Life @ 77°F (25°C), 100 gram
Handling Time @ 77°F (25°C) |
40 to 45 minutes
6 to 8 hours
|
|
Theoretical Coverage |
14 ft2 (1.3 m2) /
30 mils / liter |
|
Thickness
Minimum
Recommended |
30-60 mils
30 mils |
|
Holiday Detection |
2,000 volts |
|
Cathodic Disbondment Test (ATM
G95)
28 Days @ 77°F (25°C) - Wet |
6.7 mm
|
|
Hardness (Shore D) |
85 ± 2 |
|
Impact Resistance (ASTM
G14) |
81.8
in-lb (9/25 joules) |
|
Adhesion - Wet (ASTM D
4541-02) |
2621
psi |
|
Gouge Resistance
(Partech Method - 50 kg) |
22
mil avg. gouge depth (Holiday - Pass) |
|
Application & Service Temperature |
41°F (5°C) to 150°F (65°C) |

Handling &
Storage
|
Properties |
Data |
|
Storage |
Minimum 24 months when stored in original containers @ 41°F (5°C) to 100°F
(36°C). On job site where temperatures are below 60°F (16°C), product should
be kept warm to mix properly. |
|
Cleaning |
Clean equipment and tools with solvent (i.e., MEK or xylene). |
|
Health & Safety |
Wear protective clothing and ensure adequate ventilation. Avoid contact with
skin and eyes. See MSDS for further information. |
|
Packaging |
1 liter kit and 1 gallon kits standard. Special kit sizing also available. |

|