Installation Instructions,
Trenton Seal-Wrap
Casing End-Seal Wrapper

Description

Trenton Seal-Wrap is a casing end-seal wrapper consisting of a heavy woven glass coated with a butyl mastic of high dielectric quality. It is wrapped around the end of the casing and on the carrier pipe, and is then strapped in place with stainless steel banding.

The Trenton Seal-Wrap system was designed to enable field personnel to readily replace existing "rubber-boot" type end seals that are damaged prior to installation of casing filler. Seal-Wrap can also be used to reinforce existing "boot" or "compression" type seals. This system also has advantages for new construction. Seal-Wrap is a simple, efficient method of sealing the annular space between pipe and casing that does not necessitate absolute centering of the pipe in the casing.

Application Procedure

  1. Clean the pipe and casing ends with a wire brush to remove loose rust, coating, and dirt. Then dry off all surfaces.

  2. Brush primer on all metal surfaces to be covered with Seal-Wrap. Let dry until tacky.

  3. Place one layer of double-faced adhesive approximately 6” in from the end of the casing and 6” from the end of the casing on the carrier pipe. This is the area where the banding will be applied.

  4. Apply one wrap of Seal-Wrap around carrier and casing end. Remove the paper backing from the material as you apply the wrap. Allow a 6” overlap.

  5. Band securely in place, using one band and two buckles on both casing and carrier in the middle of the double face adhesive strips.

  6. Cover buckles with a small square of double-faced adhesive.

  7. Apply a continuous double wrap over the first wrap, making sure to start the second wrap in a different position on the pipe than the first wrap.

  8. Place 2 bands on the carrier, and 2 bands on the casing, either side of the first bands.

  9. Tighten all bands into place, so they seat into the double-faced adhesive.

  10. Let the seal cure overnight.

  11. Apply 5 psi into the top vent, check for a strong airflow out the lower end vent. This confirms there are no restrictions between vents.

  12. Then plug off the lower end vent and pressure casing to 5 psi and monitor for 15 minutes. If the air pressure holds the casing is prepared.

  13. If the casing is to be filled it is highly recommended that the ends are backfilled, this will help support the seals and help stop any minor leaks.

Material Requirements per Casing End

Casing
Diameter
Double-Faced
adhesive (feet)
Need to split
in two
Stainless Steel
Band 9 (feet)
4" 2 2 5 8
6" 4 3 6 11
8" 5 4 8 14
10" 6 5 9 17
12" 7 6 11 20
14" 8 7 12 23
16' 9 8 14 27
18" 10 9 16 30
20" 11 10 17 33
22" 12 11 19 36
24" 13 12 20 39
26" 14 13 22 42
30" 16 16 25 49
34" 18 18 28 55
36" 19 19 30 58
40" 21 21 33 64
42" 22 22 34 67

 

Corrosion Control Products Company

  

Corrosion Control Products Resources

 Search this Website
 Request Quote
 Order Products Online
 Industry Links
 CCP Suppliers
 Installation Guides
 MSDS
  

Cathodic Protection Products & Materials

  

Home

Products Search Request Quote Order Online

Corrosion Control Products Company
800-421-2623

Tel: 

 310-532-9314
Fax:  310-532-1472

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.ccpco.com

© 1996-2011Corrosion Control Products Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956