Navigation:
CCP Home > Products
> Pipeline Casing Fillers
Trenton
Short-Stop
Casing End Electrical
Insulator
Made of neoprene rubber without metal components.
Installed in casing ends for electrical insulation.

|

Trenton
Short-Stop is an easy to install neoprene
insulator with no metal parts, and is cut to
fit any size casing. |
Description
Trenton Short-Stop
casing end electrical insulator is installed in
casing ends between the carrier pipe and casing to
prevent metal-to-metal shorts. Because of its unique
slab form, it has no metal components that might
cause future shorting-out. It is made of
compression-resistant neoprene rubber. In addition
to its dielectric properties, it is resistant to
oil, water, ozone and chemicals. It withstands a
wide range of temperature variations.
Application Procedure
The casing end
annulus should be cleared of foreign matter. The
pipe is then elevated, if necessary, off the casing
inner wall. The Short-Stop insulator is placed in a
cradling fashion into the bottom of the casing
perpendicular to the longitudinal axis of the pipe.
The insulator should extend out from the casing end
approximately one inch. The pipe is then lowered
down onto the Short-Stop insulator. An additional
insulator segment is then placed over the top of the
carrier pipe.
Packaging
Short-Stop insulators
are available in 1/2 -inch and 1-inch thicknesses,
and are cut to the length required. Standard width
is 6 inches.
|

|